3810DSII Type: Low Cost Mass Flow Meter with Display | kofloc Brand

3810DSII Type: Low Cost Mass Flow Meter with Display | kofloc Brand

The Japanese kofloc manufacturer complies with SEMI and CE certification | 3810DS II is a mass flow meter with a built-in display, using a time-tested flow sensor. In addition to instantaneous flow, the 3810DS II displays total flow, an improvement over the previous model 3810DS. Like the 3810DS, the 3810DS II also has an integrated flow sensor and precision needle valve.

characteristic

・High precision needle valve for controlling very low flow and monitoring
・Two alarm outputs for flow monitoring
・Analog output is used for instantaneous flow and pulse output is used for total flow
・Lightweight and bulky design
・Built-in display integrated type, only need to connect to 24 VDC power supply.
・Flowmeter measures mass flow and directly reads flow display
・Calculation of flow correction based on temperature and pressure is not required.

kofloc brand 3810DSII type: low cost mass flow meter with display

characteristic

・High precision needle valve for controlling very low flow and monitoring
・Two alarm outputs for flow monitoring
・Analog output is used for instantaneous flow and pulse output is used for total flow
・Lightweight and bulky design
・Built-in display integrated type, only need to connect to 24 VDC power supply.
・Flowmeter measures mass flow and directly reads flow display
・Calculation of flow correction based on temperature and pressure is not required.

 

Standard

Sensing method Thermal sensor
Flow range (N2 standard gas) 10 SCCM–20 SLM 21–100 SLM
precision Within ±2% FS at 25℃ Within ±3% FS at 25℃
operating pressure 0.0–0.5 MPa (G)
Pressure resistance 1.0MPa (G)
allowable ambient temperature 0–50℃
Temperature Coefficient ±0.2% FS/°C (15–35°C)
Part material Body: SUS303, PTFE
Material in contact with gas Sealing: FKM
Option: Neoprene
Connection method Standard: Rc 1/4 (Ask us for other sizes.)
Supply voltage 24 VDC ±5%, 100 mA (option: AC adapter)
flow output signal 1–5 V, 4–20 mA (Select when ordering.)
Alarm output 2 × NPN open collector output Maximum rating: 30
VDC, 50mA

*Cable connection
Connector: 3810DS II End: HR10A-7R-6P (Hirose Electric) Cable End: HR10A-7P-6S (Hirose Electric)

*Conversion cables for older model 3810DS are available.
! ! Notice! !
Specifications related to flow range such as flow range, accuracy and repeatability are expressed in N2 or air equivalent. This product will build demand at a main pressure of 300 kPa or less and the output is open to atmosphere. Please contact us for details on pressure requirements.

 

What is a Thermal Mass Flow Meter?

hotMass flowmeteris an accurate, easy-to-install low pressure dropFlowmeter. It is suitable for flow measurement and control of dry gas applications. The application can also use heat via the gas type reference linkMass flowmeter. When the air flow changes,Mass flowmeterThe cooling effect on the heated sensor will be observed. The result is high accuracy and low cost compared to other gas flow measurement devices.

benefit:

  • high precision
  • Wide flow range, including low flow
  • Simple and durable construction
  • Easy to install and maintain
  • Flowmeterflexible connections for flow control
  • Various process connections
  • Turndown ratio 100:1
  • Low pressure drop across the flow meter
  • Provide convenient signal output

What types of mass flow controllers exist?

Thermal mass flow controllers use the thermal mass sensing technique of gases to control their mass flow. In the TMFC portfolio we have several thermal mass flow controllers, each with its own sensor technology:

Mass flow controllers using bypass sensors. These devices, such as TMFCs and TMFMs, are ideal for clean and dry gas applications where greater precision and repeatability are required.
Mass flow controller using the on-line principle. Series such as the TMFC and TMFM series are perfect if your application has high purity gases above 99.9%, or when high repeatability and robustness are more important than accuracy.
Gas mass flow controller using piping control technology. These series stand out because they can measure gas flow and control.
Whenever your mass flow needs to be displayed and over a wide flow range, a gas series using MEMS chip sensor technology such as the TMFM6000 is perfect.
Gas mass flow controllers using in-line (CMOS) technology.

Mass Flow Controller ( MFC ) Principle / Flow Controller Principle

A mass flow controller (MFC) is a device used to measure and control the flow of liquids and gases. [1] Mass flow controllers are designed and calibrated to control a specific type of liquid or gas over a specific flow range. The MFC can have a set point between 0% and 100% of its full scale range, but typically operates within the full scale range of 10% to 90% for best accuracy. The device will then control the flow rate to the given set point. MFCs can be analog or digital. Digital flow controllers are usually capable of controlling more than one fluid, while analog controllers are limited to the fluids they are calibrated for.

All mass flow controllers have an inlet port, an outlet port, a mass flow sensor, and a proportional control valve. The MFC is equipped with a closed loop control system where the operator (or external circuit/computer) provides an input signal which is compared with the value of the mass flow sensor and adjusts the proportional valve accordingly to achieve the desired flow. Flow is specified as a percentage of its calibrated full scale flow and is provided to the MFC as a voltage signal.

Mass flow controllers require the supply gas or liquid to be within a specific pressure range. Low pressure will deplete the MFC of fluid and prevent it from reaching its set point. High pressures may cause erratic flow rates. There are many different technologies that help measure the flow of fluids and ultimately help control flow. These technologies define the types of mass flow controllers and they include differential pressure (ΔP), differential temperature (ΔT), Coriolis force, ultrasonic, electromagnetic, turbine, etc.

mass flow controller, mass flow controller
mass flow controller, mass flow controller, mfc principle structure description

Mass Flow Meter Installation

Now there are more and more applications of mass flowmeters, and some occasions where mass flowmeters are installed for the first time are not clear about the installation method of mass flowmeters, reverse installation, wrong installation, etc., which affect the normal use of the equipment. This article discusses this problem Describe in detail how to install a mass flow meter.

Excessive mechanical stress during sensor installation will affect the zero point of the mass flowmeter. If these stresses are constantly changing, the zero point drift of the meter will cause inaccurate measurement and cannot work normally. Therefore, the correct installation of the mass flowmeter is an important part of ensuring the normal operation of the equipment.

1. Choose the installation method

The installation method of the sensor is mainly determined according to the phase difference of the fluid and its process conditions. There are three installation methods.

1. If the measured fluid is a liquid, the sensor is generally installed with the shell facing down to avoid air accumulation in the vibrating tube of the sensor, so as to achieve the purpose of accurately measuring the mass flow rate.

2. If the measured fluid is gas, the sensor is generally installed with the shell facing upwards to avoid accumulation of condensate in the sensor vibration tube.

3. If the measured fluid is a mixed slurry of liquid and solid, install the sensor on a vertical official road, which can prevent particles from accumulating in the sensor's Coriolis force measuring tube. In addition, if the process pipeline needs to be cleaned with gas and steam, this installation method can also facilitate cleaning, but this installation method is more difficult to fix than the previous two, and the pressure loss is larger.

Mass flow meter installation method
Mass flow meter concept installation

 

 

 

 

 

gas flow controller

gas mass flow controllers

Mass Flow Formula

Types of mass flow meters

mass flow meter english

according toThree degrees Chinese website.Multiple interpretations mass flowmeter【electronic computer term】mass flow meter【mechanical engineering】mass flowmeter sensor【marine science term-underwater engineering】thermal mass flow【electronic engineering】mass flow measurement【electrical engineering】

What is the use of electromagnetic flowmeter? | Our performance

What is a mass flow meter used for? | Our performance

What is the use of vortex flowmeter? | Our performance

What is the use of ultrasonic flowmeter? | Our performance

What is a gear flow meter used for? | Our performance

What is a float flow meter used for? | Our performance

 

Application

Flow Meter

Types of

Electronic

Installation method

Thread

Output method

switch, analogy

Product Dimensions

Product size chart download

FGT authorized Taiwanese sellers for kofloc (more than 10 years of cooperation experience between the two parties)
The certified warranty sticker has been verified by the FGT secondary quality inspection label

manual

Product manual download

FGT authorized Taiwanese sellers for kofloc (more than 10 years of cooperation experience between the two parties)

The certified warranty sticker has been verified by the FGT secondary quality inspection label

Communication Brochure

Communication Development Manual Download(This product has no communication output)

FGT authorized Taiwanese sellers for kofloc (more than 10 years of cooperation experience between the two parties)

The certified warranty sticker has been verified by the FGT secondary quality inspection label

certified

3810dsii type: low cost mass flow meter with display | kofloc brand first general technology inc. | first general technology inc.European Conformity Certification - Wikipedia, the free encyclopedia

Special needs

Flow meter requirements

Flow meter requirements

fluid type
flow unit
Pipeline unit
Installation mode
Inquiry form