FGT think your best choice in the future
System Integration Designers in FGT
LCD display multi-function digital panel instrument Model MX4W series | Autonics brand
Autonics brand MX4W series digital panel meters
LCD display with large, easy-to-read white PV characters (display height: 19 mm). The DIN W 96 x H 48 mm panel meter also features a 12-segment display that can be used to display various alphanumeric characters. The series also features multiple input options for a variety of setups. The input and power terminals are isolated, allowing multiple units to be powered by the same power source.
MX4W Series Digital Panel Meters
LCD display with large, easy-to-read white PV characters (display height: 19 mm). The DIN W 96 x H 48 mm panel meter also features a 12-segment display that can be used to display various alphanumeric characters. The series also features multiple input options for various setups. Input and power terminals are isolated, allowing multiple units to be powered from the same power supply. Panel meters also have various other options, including a power factor display function for displaying the analog output of the power factor converter. The compact 20mm rear length dimension allows flexible installation in limited spaces.
Autonics MX4W is a series of digital panel meters manufactured by Autonics. Here are some key features and information about the MX4W series:
The MX4W series digital panel meters feature an LCD display with large, easy-to-read white PV characters. Display height is 19mm.
The panel dimensions of the MX4W series are DIN W 96 x H 48 mm.
The MX4W series offers multiple models with different specifications and functions.
When using the unit at low temperatures (below 0°C), the display cycle of the MX4W-A-FN and MX4W-A-F1 models may become slower due to the characteristics of the LCD. However, the control output operates normally.
Before using the MX4W series, it is recommended to read the safety precautions and specifications provided in the manual.
If you need more specific information about a specific model or have any other questions, please feel free to ask!
main feature
- LCD display with easy-to-read white PV characters
- Isolated input and power modules allow multiple units to be powered from a single power supply
- Compact, space-saving design (rear length: 20 mm)
: Compared with the same DIN size panel meter (MT4W), the rear length dimension is reduced by 80% - Multiple input options (by model)
– Input options: DC/AC voltage, DC/AC current - Maximum allowable input: 500 VDC, 500 VAC, DC 5 A, AC 5 A
- Display range: -9999 to 9999
- Upper and lower limit display scale function
- AC frequency measurement (range: 0.100 to 1200 Hz)
- Preset output: OUT1, OUT2 (NPN/PNP open collector output)
- Power factor display/output function
: Displays the analog output of the power factor converter (1-5 V, 4-20 mA) as -0.50~1.00~0.50 - A variety of functions
: Peak display value monitoring, display cycle delay, zero adjustment, peak display value correction, etc. - Power supply: 24-240 VAC 50/60 Hz, 24-240 VDC universal
LCD Monitor
reduce rear length
12 segment display
various inputs
Zoom
Shared power
Power factor display
Large LCD display with easy-to-read white PV characters
Large LCD display with large PV characters (display character height: 19mm) makes it easier to read status in various environments.
-
The display is highly visible from various viewing angles.
12-segment display improves readability
The 12-segment display improves the readability of alphanumeric characters.
Offers a variety of input options
Various input options are available, including DC voltage/current negative input, and also supports OUT1 and OUT2 preset outputs for flexible application in various user environments.
Compact design with 20 mm rear length
The rear length has been reduced 80% compared to Autonics' similarly sized (DIN 96 x 48 mm) model (MT4W). The rear has a length of 20mm for easy installation in limited spaces.
Isolated input, output, power module
Isolated input, output and power modules allow multiple units to be powered from a single power supply.
Power factor display and output
Displays the analog output of the power factor converter (1-5 V, 4-20 mA) as -.0.50~1.00~0.50, and can also output according to the preset operating mode settings.
Upper and lower limit display scale function
The high/low display scale function allows the user to select and display the minimum and maximum values of the target input.
Application
-
Factory switchboard panel dashboard
Digital panel meters are used in factory and building switchboards to display a variety of data, including voltage, current, and power factor.
Digital Panel Meterinformation
Digital Panel Meteris a digital display designed to be installed in a panel such as a control panel. They usually read some type of input, be it voltage, current, or resistance, and display its value digitally. Typically, this input is a measurement from a sensor that is converted and displayed as temperature, pressure, or other system variable. These meters can also act as simple controllers, triggering a switch or performing a simple function when a reading reaches a preset measurement.
Function
To choose a digital panel meter, industrial buyers must first decide what they want to do.
Basic display output
allDigital Panel MeterThe basic function performed is to take the input signal and convert it to a display value. This input initially comes from a sensor in the process or system and is sent to the device through the panel to which the meter is connected. This panel provides power to the device and provides input to the display.
basicDigital Panel Metersignal flow
Additional output
In addition to simple displays, someDigital Panel MeterThere are also optional control or interface functions.
- simulationFunctional means that a device can provide an analog output (such as a variable voltage or current) proportional to the input signal, for use in an analog device.
- Data interfaceFeatures allow users to interact with information displayed for data analysis.
- set pointFunctions allow the user to preset input values that will activate an alarm or simple control function. These on/off functions correspond to solid state or electromechanical relay outputs, depending on the design.
Flowchart – Dual Channel Function with Additional Optional Outputs. Image Credit: Laurel Electronics
Types of
Once buyers have determined which features they need, the actual type of meter also needs to be considered.
Digital Panel MeterDifferentiated by type based on their display and lighting technology.
show performance
Digital Panel Meteris displayed numerically or alphanumerically.
- numberDisplay means that the meter only displays numbers. Most digital panel meters are digital because the main purpose of the meter is to display numerical values.
- letter and numberDisplay means that the meter displays both numbers and letters. This is useful for providing more information to the user, such as the corresponding channel or unit to read.
Technology
The lighting used in digital displays is LED or LCD.
- led(Light Emitting Diode) The display consists of diodes that light up the segments. The LED display can be seen in the dark.
LCD(Liquid Crystal Display) technology to display dark/black numbers on a blank grey or green screen. LCDs consume less power than LEDs, but require a backlight to see in the dark.
Signal input type
In order to work properly, the device must be designed to accept the analog input sent to it. Input types include:
- AC voltage– Input is received as a measurable form of AC voltage in AC voltage (VAC).
- Alternating current– Enter the AC current sink in a measurable form in milliamps (mA AC) or amps (A AC).
- AC power– Inputs are received as adjustable ranges for AC current, voltage and/or frequency.
- DC voltage– Inputs are received as a measurable DC voltage in Volts Direct Current (VDC).
- DC– Enter a measurable form of DC current sink in milliamps (mA DC) or amps (A DC).
- DC power supply– Inputs are received as adjustable ranges for DC current, voltage and/or frequency.
- resistance– Inputs come from components that measure resistance changes, e.g.Piezoresistive sensororstrain gauge.
- Temperature Controller-According to temperature changes fromThermocouple,RTDorThermistorReceive input. For more information, seeTemperature Sensorarea.
Specification
There are some important specifications to consider when choosing a digital panel meter, all of which relate to the display itself. These include the number of bits, the size of the panel face, and the display color.
number of digits
The number of digits determines how many digits are in the display output. This number should be less than or equal to the number of significant digits in the signal input, depending on the desired precision. Displays half digits at nominal (e.g. 4 .5digits, 2 .5digit), the first or last digit can only be "1" or off, or "5" or off. This "half" number allows the upper limit of the display to be extended (1 000 vs. _999) or allow to display intermediate values (100. 5 vs. 100_).
size
The size of the panel face determines the physical compatibility of the device with the panel on which it is installed. Typically, face dimensions are in inches (” or in) or millimeters (mm) and are specified by length and width. Sometimes, the depth of the gauge and the size of the cutout need to be considered, although most panels will accept standard depth and face dimensions Related. Also, the display should be large enough for the user to read the numbers/letters comfortably when installed.
colour
Digital panel meters are designed to display certain colors. In LCD meters, the color is determined by the backlight behind the black numerals. In LED meters, the color is determined by the type of diode built into the device. Color options include:
- Red
- green
- amber
- blue
- yellow
- tangerinr
- aquarium
Red is the default LED color, usually LCDs have no backlight (no color). Multicolor options exist, which are especially useful when using multiple monitors or channels. Setting a color for each monitor can help users quickly identify each monitor.
connect
digital display instrumentThe connections include electrical inputs and outputs as well as physical connections (such as screw connectors) necessary for safe mounting to the panel. These connections must be compatible with the design and regulations of the relevant panel.
feature
Digital Panel MeterMay contain many functions that provide additional functionality to the device. These include set point options, alarms, on/off controls and adjustable displays.
- Set point optionsAbility to set control limits or set points for process parameters such as speed, temperature, pressure or humidity. In heating applications, the unit sends an off control signal when the set point temperature is approaching or exceeded, and an on control signal when the temperature is below the set point.
- Can be built into the meteralarm(audio or visual) to indicate when a limit or set point is reached.
- On/Off ControlAllows the meter to send a switch output signal to activate or deactivate a processing unit (oven, motor, fan, etc.) using relays, open collector transistors, or other techniques. Switch, pop or limit control is one of the simplest process control techniques.
- adjustable displayAllows the gauge to be adjusted to show different displays.
- Additional channelAllows digital panel meters to receive and interpret multiple signals from different sources.
- USB/Serial PortAllows the meter to connect to other devices, such as data analysis tools or computers, via a USB or serial connector.
The principle of timer counter table | Our performance
Rotary encoderprinciple| Our performance
Photoelectric switch principle | Our performance
Principle of safety grating | Our performance
Proximity switch principle | Our performance
Principle of digital display meter | Our performance
Stepper Motor &Drive principle | Our performance