Resin material area flowmeter RK20T series

Resin material area flowmeter RK20T series

Japanese kofloc manufacturer complies with SEMI and CE certification ■ RoHS certification | RK1000 series This is a glass tube rotameter. ■Fluid Air, N2, O2, H2, He, Ar, CO2 ■Flow range 100mL, 150mL, 200mL, 300mL, 500mL/min 1L, 2 liters, 3 liters, 5 liters, 10 liters, 15 liters, 20 liters/min ■Accuracy FS±5% (measurement point)

Resin material area flowmeter RK20T series

RK20T series are compact and lightweight resin material area flowmeters. There are two types with valve and without valve to choose from. Designed for easy flow reading, these meters are ideal for air sampling equipment, medical equipment, analytical equipment, purge systems, water treatment equipment, and more.

feature

  • low price
  • short lead time
  • Resin is lightweight and compact
  • easy to read

Application

  • For integration into device panels
  • for gas purging systems
  • For measuring welding gas flow
  • Suitable for all types of analyzers
  • for semiconductor manufacturing equipment

Standard Specifications

■Fluid
air, nitrogen, water
For other gases, it is necessary to consult the conversion conditions or to calibrate with the actual gas to be used.
■Flow range
Air
Flow range
0.05-0.5 L/min 0.15-1.0 L/min 0.5-5.0 L/min 1.0-10L/min 2.5-25 L/min 5-50 L/min 20-100 L/min
water
2.5-25mL/min 30-300mL/min 100-800mL/min 200-1600mL/min 500-2800mL/min
■Accuracy FS±6% (measurement point)
■Voltage resistance

0.7 MPa(G)
■Product material

MaterialABS
Tapered Tube Material: Acrylic
Float: hard glass, SUS316, SUS303
Sealing ring: packing fluororubber
■RoHS certification

● Principle of area flowmeter

How it works

  1. Through the change of the cross-sectional area of the pipe diameter from the bottom to the top of the fluid, the buoyancy of the float, the liquid pulling force, the thrust force and the gravity are mutually balanced to measure the flow rate.
  2. The flowmeter must be installed vertically.
  3. Because of the buoyancy, the specific gravity of the liquid and the float material must be considered.
  4. The difference in shape processing will affect the strength of fluid pulling force and upward thrust.
  5. There is a difference in accuracy between flowmeters with guide rails and those without guide rails. The difference comes from the fact that the finished product of flowmeters with guide rails is just right because of the size of the rails. When the float moves in the flow field, it will not deviate greatly from the axis, so it is more accurate. In contrast, the float of a flowmeter without a guide rail does not move accurately, and is easy to deviate from the axis, and there will be a large range of offset. Therefore, generally speaking, the presence or absence of guide rails does have a relationship with accuracy.
  6. Low-priced flowmeters launched by non-branded or counterfeit factories have rails that are skewed due to rail design and processing problems. In addition, some manufacturers are making chemical-resistant plastic track products. When they leave the factory, the track is obviously skewed, and the skew of the track may easily lead to inaccurate flowmeters.
  7. The main body is made of polymer material, and it is sprayed (formed) by injection, with high precision and small tolerance. Product performance is better than glass tube.
  8. The price of the area flowmeter is carefully evaluated and produced in every detail, and the product is customized for the customer's needs, and it is strictly checked before leaving the factory.
  9. If there is no obvious damage to the flowmeter, problems such as float jumping, abnormal movement, and flow instability occur, most of which are piping problems, and may be abnormal conditions such as pipeline motors and pressure storage tanks, resulting in large changes in flow.

 

What is the use of electromagnetic flowmeter? | Our performance

What is a mass flow meter used for? | Our performance

What is the use of vortex flowmeter? | Our performance

What is the use of ultrasonic flowmeter? | Our performance

What is a gear flow meter used for? | Our performance

What is a float flow meter used for? | Our performance

paddle wheel flowmeter|rotameter flowmeter installation|

Application

Flow Meter

Types of

Mechanical

Installation method

mouth, plate

Product Dimensions

Product size chart download

FGT authorized Taiwanese sellers for kofloc (more than 10 years of cooperation experience between the two parties)

The certified warranty sticker has been verified by the FGT secondary quality inspection label

Product Manual

Product manual download

FGT authorized Taiwanese sellers for kofloc (more than 10 years of cooperation experience between the two parties)

The certified warranty sticker has been verified by the FGT secondary quality inspection label

certified

Resin material area flow meter rk20t series First General Technology Co., Ltd. | first general technology inc.European Conformity Certification - Wikipedia, the free encyclopediaResin material area flow meter rk20t series First General Technology Co., Ltd. | first general technology inc.RoHS certification

Special needs

Flow meter requirements

Flow meter requirements

fluid type
flow unit
Pipeline unit
Installation mode
Inquiry form

You may also like…