TPC Type:PID Temperature Controller

  • Frequently uses the parameter may freely arrange to commonly used position
  • T/C,RTD.Linear input selectable
  • Auto/Manual Control mode optional
  • Duplex Output Mode(heat/Cool) Through 2 control processes
  • Alarm Up to 3 alarm set
  • CT for heater break alarm
  • Programmable mode up to 8 ramp/soak segments
  • Operates on any line voltage form 90V AC to 260V AC at 50/60Hz
  • Option RS232 and RS485 communication interface Modbus RTU available
  • Open loop motor valve control
  • Remote set-point
  • Soft start Retransmission output

請先註冊/登入後,即可下載產品型錄。

描述

  • Frequently uses the parameter may freely arrange to commonly used position
  • T/C,RTD.Linear input selectable
  • Auto/Manual Control mode optional
  • Duplex Output Mode(heat/Cool) Through 2 control processes
  • Alarm Up to 3 alarm set
  • CT for heater break alarm
  • Programmable mode up to 8 ramp/soak segments
  • Operates on any line voltage form 90V AC to 260V AC at 50/60Hz
  • Option RS232 and RS485 communication interface Modbus RTU available
  • Open loop motor valve control
  • Remote set-point
  • Soft start Retransmission output

Technical Specifications

Model TPC484 TPC489 TPC964 TPC727 TPC969
Dimension(WxD) 48x48mm 48x96mm 96x48mm 72x72mm 96x96mm
Input Type Termocouple K,J,R,S,B,E,N,T,W3,W5,PL-II(Input impedance:Approx.1MΩ
RTD PT-100(DIN),JPT-100(JIS)
Linear Analog 0~10mV,0~20mV,0~50mV,4~20mA,0~10V…Please refer to Input Type List.
Controlling Output Relay A Contact 5A/250V A,B contact 8A/250V
Logic Voltage PWM Pulse voltage(to drive SSR):On=24V;Off=0V(20mA Max.)
Linear Analog Currect:0~20mA,4~20mA(Inputimedance:600Ω Max.)                                                                                                                                                             Voltage:0~5V,1~5V,0~10V,2~10V(Inputimpedance:1KΩ Min.)Resolution:Approx.1,000 scales
Controlling Method Controlling selection of ON/OFF,P,PI,PD,PID
Accuracy 0.2%FS±1DIG(except thermocouple type B&S)
Alarm Output Relay Contact 8A,250VAC
Data Backup Memory EEPROM,10Years
Storage/Operating Environment 0~65℃/0~50℃,20~90%RH
Digi Height(mm) PV(Red) 8 8 13 14 14
SV(Green) 8 8 10 10 10
Power Consumption(Approx.) 4VA 4VA 4VA 5VA 5VA
Power Supply AC 90~240V(60/50Hz),DC24V(optional)
Net Weight(Approx.) 130g 200g 200g 200g 280g

Application

What is PID Controller

proportional–integral–derivative controller (PID controller. or three-term controller) is a control loop mechanism employing feedback that is widely used in industrial control systems and a variety of other applications requiring continuously modulated control. A PID controller continuously calculates an error value  as the difference between a desired setpoint (SP) and a measured process variable (PV) and applies a correction based on proportionalintegral, and derivative terms (denoted PI, and D respectively), hence the name.

In practical terms it automatically applies accurate and responsive correction to a control function. An everyday example is the cruise control on a car, where ascending a hill would lower speed if only constant engine power were applied. The controller’s PID algorithm restores the measured speed to the desired speed with minimal delay and overshoot by increasing the power output of the engine.

The first theoretical analysis and practical application was in the field of automatic steering systems for ships, developed from the early 1920s onwards. It was then used for automatic process control in the manufacturing industry, where it was widely implemented in pneumatic, and then electronic, controllers. Today the PID concept is used universally in applications requiring accurate and optimised automatic control.

PID controller application

In theory, a controller can be used to control any process which has a measurable output (PV), a known ideal value for that output (SP) and an input to the process (MV) that will affect the relevant PV. Controllers are used in industry to regulate temperaturepressureforcefeed rate,[15]flow rate, chemical composition (component concentrations), weightpositionspeed, and practically every other variable for which a measurement exists.

1.Environmental control

2.Smart Manufacturing Automation

Size Rang

Model TPC484 TPC489 TPC964 TPC727 TPC969
Dimension(WxD) 48x48mm 48x96mm 96x48mm 72x72mm 96x96mm
Input Type Termocouple K,J,R,S,B,E,N,T,W3,W5,PL-II(Input impedance:Approx.1MΩ
RTD PT-100(DIN),JPT-100(JIS)
Linear Analog 0~10mV,0~20mV,0~50mV,4~20mA,0~10V…Please refer to Input Type List.
Controlling Output Relay A Contact 5A/250V A,B contact 8A/250V
Logic Voltage PWM Pulse voltage(to drive SSR):On=24V;Off=0V(20mA Max.)
Linear Analog Currect:0~20mA,4~20mA(Inputimedance:600Ω Max.)                                                                                                                                                             Voltage:0~5V,1~5V,0~10V,2~10V(Inputimpedance:1KΩ Min.)Resolution:Approx.1,000 scales
Controlling Method Controlling selection of ON/OFF,P,PI,PD,PID
Accuracy 0.2%FS±1DIG(except thermocouple type B&S)
Alarm Output Relay Contact 8A,250VAC
Data Backup Memory EEPROM,10Years
Storage/Operating Environment 0~65℃/0~50℃,20~90%RH
Digi Height(mm) PV(Red) 8 8 13 14 14
SV(Green) 8 8 10 10 10
Power Consumption(Approx.) 4VA 4VA 4VA 5VA 5VA
Power Supply AC 90~240V(60/50Hz),DC24V(optional)
Net Weight(Approx.) 130g 200g 200g 200g 280g

Order Information

Order Information
TPC Code Dimension Size Type
 

 
484 48x48mm
  489 48x96mm
  964 96x48mm
  727 72x72mm
  969 96x96mm
   

 
Code Input Type
    0 Thermocouple(Standard Type)
    1 RTD
    2 4~20mA
    3 0~5Vdc
    4 1~5V
    5 0~10V
     

6
2~10V
      Code Output#1 Type
      0 Null
      1 Relay(Standard Type)
      2 Logic Voltage(SSR Control)
      3 4~20mA
      4 0~5V
      5 1~5V
      6 0~10V
      7 2~10V
      8 3-line proportional motor controlling
       

 
Code Output#2 Type
        0 Null(Standard Type)
        1 Relay
        2 Logic Voltage(SSR control)
        3 4~20mA
        4 0~5V
        5 1~5V
        6 0~10V
        7 2~10V
         

 
Code Alarm Type
          0 Null(Standard Type)
          1 1 Set
          2 2 Sets
          3 3 Sets
          A HBA(50A)*1
          B HBA+AL2
          C HBA+AL2,3
          D HBA(100A)
          E HBA+AL2
          F HBA+AL2,3
           

 
Code Transmitting Output Type
            0 Null(Standard Type)
            3 4~20mA
            4 0~5V
            5 1~5V
            6 0~10V
            7 2~10V
             

 
Code Remove SV Type
              0 Null(Standard Type)
              3 4~20mA
              4 0~5V
              5 1~5V
              6 0~10V
              7 2~10V
               

 
Code Communication Type
                0 Null(Standard Type)
                1 RS232
                2 RS485
                 

 
Code Water Proof Type
                  N No Blank(Standard Type)
                  P Yes
                   

 
Code Power Supply Type
                    A AC 90~240V(Standard Type)
                    D DC/AC 24~40V
                     

 
Code Logo
                      F FGT Logo(Standard Type)
                      C Customer Logo
                       

 
   
TPC                       Complete Ordering Code
*Note:If HBA function is available,AL1 function will be disabled.Select suitable amperage(50 or 100A) according to the load currect magnitude.
*Note:HBA and RSV cannot be allocated together.
*Note:Using customer Logo launch to more than 100 united for  one year
立即詢價
close slider
詢價表單