FMG-J Insertion magnetic Flow Meter, measurement analysis instrument flow meter

Model No. : FMG-J
Made in : Taiwan

  • Image

    Specifications

    • Smart Intelligent LCD display function
    • Display Interface: English or Chinese
    • Easy to Setup and install/Variety of sizes range.
    • High Accuracy:±1.5% of reading(RD)

    • Flow direction function: Plus or Reverse
    • Alarm Function: Excitation and No fluid tubes Alarm.
    • Install Way: Adjustable and Fixed type.
    Model FMG-J FMG-I
    Adjustable Type Fixed Type
    Size(mm) 100~3000
    Application Raw Water,Pure Water,Waste Water,Liquid of Conductivity >50μS/cm
    Peak flow rate 0.1~10.0 m/s
    Conductivity to be more than 50μS/cm
    Accuracy ± 1.5% of  reading
    Repeatability ± 0.25% of reading
    Insertion tube size(mm) ø32mm or ø50mm
    Material of signal electrode and grounding electrode Mo-containing stainless steel,Hastelloy B,Hastelloy C,Titanium alloy,Tantalum alloy,Platinum-iridium alloy,Stainles-steel-coated wolfram
    Material of Piping Carbon Steel、Stainless steel 304、No piping
    Material of sensor Stainless steel 1Cr18Ni9Ti
    Max.Temperature with Lining material Polytetrafluoroethylene <70℃
    Polyvinyl fluoride <70℃
    Fluorinated ethylene-propylene <70℃
    Polychloroprene rubber <70℃
    Polyurethane <70℃
    Max.Pressure DN100~DN3000 ≦1.6Mpa
    Display Line 2 Line with LCD
    Protection IP68 for Body and IP65 for Display
    Output 4~20 mA or 0~10mA or pulse
    Communication RS485(Option)、RS232(Option)、Hart(Option) with lightning protection
    Parts Vavle With Without
    Power supply AC 85~265V 45~63Hz or DC 11~40V

    Sensor performance comparison:

    Comparison item

    Insertion Electromagnetic Flow Meter

    Clip Ultrasonic Flow Meter

     

    Sewage, Normal Water, Waste Water,

    Chemical Liquid

    No-hybrid Water

    Measurement of fluid

     

    Insertion

    Clip

    Install way

     

    Openings can be inserted

    Require precise distance measur

    sensors

    Installation method

     

    1.5%RD

    3%FS

    Accuracy

     

    No effect

    Affected

    Bubble effect

     

    Without full pipe flow as measured

    Required full flow pipe detection

    Measurement Capability

     

    No effect

    Affected

    Contamination problems

     

    Compact installation

    Separate installation

    Display

    No fluid Alarm

    With

    Without

     
         

    Comparison item

    Insertion Electromagnetic Flow Meter

    Rotor Flow meter

    Measurement of fluid

    Sewage, Normal Water, Waste Water,

    Chemical Liquid

    No-hybrid Water

    Install way

    Insertion

    Flange

    Installation method

    Openings can be inserted

    Need to cut pipe installation

    Accuracy

    1.5%RD

    3~5%FS

    Bubble effect

    No effect

    No effect

    Measurement Capability

    Without full pipe flow as measured

    Rotor measuring

    Contamination problems

    No effect

    Affected

    Display

    Compact installation

    Compact installation

    Malfunction rate

    Low

    High

    Life time

    Long

    Short

    No fluid Alarm

    With

    Without

    Applications:

    Image

    Flow range& Overall structure

    DN Flow Range(m3/h)
    (mm) Qmin(0.5m/s) Q(1.0m/s) Q(2.0m/s) Q(3.0m/s) Q(4.0m/s) Q(5.0m/s) Q(6.0m/s) Q(7.0m/s) Q(8.0m/s) Q(9.0m/s) Qmax(10 m/s)
    100 20 39 79 117 157 196 235 275 314 353 393
    125 29 57 115 171 229 286 343 401 458 515 573
    150 40 80 161 240 320 400 480 561 641 721 802
    200 62 124 250 374 498 623 747 872 997 1121 1247
    250 91 181 364 545 726 909 1090 1271 1454 1635 1818
    300 127 254 509 763 1017 1272 1526 1780 2035 2289 2545
    350 173 346 692 1039 1385 1731 2077 2423 2769 3116 3464
    400 226 452 904 1356 1809 2261 2713 3165 3617 4069 4523
    450 286 572 1145 1717 2289 2861 34347 4006 4578 5150 5725
    500 353 707 1413 2120 2826 3533 4239 4946 5652 63559 7069
    600 509 1017 2035 3052 4069 5087 6104 7122 8139 9156 10180
    700 692 1385 2769 4154 5539 6924 8308 9693 11078 12463 13847
    800 904 1809 3617 5426 7265 9043 10852 12660 14469 16278 18086
    900 1145 2289 4578 6867 9156 11445 13734 16023 18312 20602 22891
    1000 1413 2826 5652 8478 11304 14130 16956 19782 22608 25434 28260
    1200 2035 4069 8139 12208 16278 20347 24417 28486 32556 36625 40694
    1400 2769 5539 11078 16617 22156 27695 33234 38773 44312 49851 55390
    1600 3617 7235 14469 22156 28938 36173 43407 50642 57876 65111 72346
    1800 4578 9156 18312 28938 36625 45781 54937 64094 73250 82406 91562
    2000 5652 11304 22608 33912 45216 56520 67824 79128 90432 101736 113040
    2200 6839 13678 27356 41034 54711 68389 82067 95745 109423 123101 136778
    2400 8139 16278 32556 48833 65111 81389 97667 113944 130222 146500 162778
    2600 9552 19104 38208 57311 76415 955519 114623 133726 152830 171934 191038
    2800 11078 22156 44312 66468 88623 110779 132935 155091 177247 199403 221558
    3000 12717 25434 50868 76302 101736 127170 152604 178038 203472 228906 254340